EXAMPLE / 04 FLOORS
Lifted floorboards at a bathroom entrance
The report recommended refixing the loose boards and investigating the concealed floor timbers.
Enlarge photograph Exposed pipework and debris beneath lifted floorboards at a bathroom entrance.
ANONYMISED REPORT SUMMARY
Level 3 / 6d · Floors
- 01What was observed
- Boards were already lifted at the bathroom entrance, with loose boards and debris beneath. No signs of rot or wood-boring insect attack were seen in the timbers visible through that opening. The ground-floor joists were wholly concealed.
- 02What the report concluded
- The visible timbers could be examined only through one opening. A noticeable first-floor slope was also recorded, with its cause unresolved.
- 03What remained uncertain
- The floor voids were not inspected and no ground-floor access hatch was noted. The ground-floor joists remained concealed, and the assumed suspended timber construction had not been verified.
- 04What was recommended
- Refix the loose bathroom boards and reinstate the lifted boards with a joiner. Include concealed timbers and bearings, decay, insect attack and the floor slope in the scoped damp and timber investigation. The same element called for a Refurbishment and Demolition asbestos survey before legal commitment, to scope materials that the planned works would disturb.
Checked against the issued Level 3 report from Stockport: 6d · Floors; pages 35–36; photograph 49. Reviewed 22 November 2026. Wording is an anonymised summary, rather than a reproduction of the report.