EXAMPLE / 02 ROOF SPACE
Fallen polystyrene tiles in a roof space
The report recommended removing the loose tiles and checking roof-space ventilation and wiring.
Enlarge photograph Fallen polystyrene tiles on the insulation at ceiling level.
ANONYMISED REPORT SUMMARY
Level 2 / 6a · Roof structure
- 01What was observed
- Polystyrene tiles had been fitted between the rafters beneath a breathable membrane. Many had fallen onto the loose-fill mineral wool at ceiling level. No condensation or staining was noted in the roof space.
- 02What the report concluded
- With insulation already at ceiling level, the report explained that the rafter tiles added little and loose tiles could obstruct ventilation at the eaves. It also identified the material's combustibility and the potential for contact with PVC cable sheathing to damage it over time.
- 03What remained uncertain
- The reported EPC insulation depth was not measured during the inspection. The report did not record an electrical test or confirm damaged cable sheathing; roof-space ventilation still needed to be checked.
- 04What was recommended
- A roofing contractor was to remove the fallen and remaining polystyrene tiles, rather than refix them, and confirm adequate ventilation. The electrician carrying out the Electrical Installation Condition Report was to check the roof-space wiring.
Checked against the issued Level 2 report from Coventry: 6a · Roof structure; pages 29–30; photograph 34. Reviewed 22 November 2026. Wording is an anonymised summary, rather than a reproduction of the report.