Blocked gutters and a disconnected downpipe

What an issued Level 2 report in Sheffield recorded, with the inspection photograph and the original advice.

EXAMPLE / 07 RAINWATER PIPES AND GUTTERS

Debris and vegetation in a gutter

The report recommended clearing the gutters, checking leaks and falls, and repairing the garage drainage details.

Debris and vegetation collected in the gutter beside a tiled roof slope.Enlarge photograph
THE ORIGINAL PHOTOGRAPH

Debris, moss and vegetation in the side gutter.

ANONYMISED REPORT SUMMARY
Level 2 / 5c · Rainwater pipes and gutters

2
01What was observed
The report recorded debris, mortar, moss and vegetation in the gutters. It also recorded a missing stop end and a garage downpipe discharging directly into the ground.
02What the report concluded
The visible obstruction and incomplete rainwater details were defects requiring attention. The report explained the risk of water discharging onto adjacent walls and ground.
03What remained uncertain
Leaks and gutter falls still needed to be checked after clearance.
04What was recommended
A roofing contractor was to clear the gutters, check leaks and falls, fit the missing stop end and connect the garage downpipe to a gully or drainage system, alongside the roof repairs.
Why this element was rated 2

Rainwater pipes and gutters were rated 2 because clearing and repairs were needed.

Checked against the issued Level 2 report from Sheffield: 5c · Rainwater pipes and gutters; pages 21–22; photograph 15. Reviewed 22 November 2026. Wording is an anonymised summary, rather than a reproduction of the report.

Questions for a follow-up call

  • Does the contractor’s scope include the stop end, falls and discharge point?
  • How will the contractor check for leaks once debris has been cleared?

Use the findings and timeframes in your own report when discussing a different home.

Organise the answers in your report action planner