EXAMPLE / 10 ROOF SPACE
Staining on a roof membrane
The report recommended a damp and timber investigation and an assessment of roof-space ventilation.
Enlarge photograph Staining on the roof membrane near the eaves.
ANONYMISED REPORT SUMMARY
Level 2 / 6a · Roof structure
- 01What was observed
- Black mould was recorded on the sarking membrane, with staining to timbers and adjoining masonry. The accessible roof space was dry at the time of the inspection.
- 02What the report concluded
- The report associated the membrane mould with roof-space condensation. It separately stated that the source and age of the staining could not be confirmed visually.
- 03What remained uncertain
- The inspection did not establish whether wetting was continuing or whether decay or insect attack was present. Boarding, stored goods and concealed insulation restricted what could be examined.
- 04What was recommended
- A damp and timber specialist was to investigate the timber condition and possible continuing wetting, alongside the cellar and concealed floor concerns. A roofer was to assess ventilation and inspect the stack and flashings.
Checked against the issued Level 2 report from Ossett: 6a · Roof structure; pages 25–26; photograph 25. Reviewed 22 November 2026. Wording is an anonymised summary, rather than a reproduction of the report.